Integrations

Choose the systems that fit the project.

GEM brings supported equipment and open protocols into one operating model without forcing the property into a single manufacturer’s catalog.

Three integration paths

Start with the shortest reliable path.

A product driver is often the answer, but GEM also exposes native protocol and developer surfaces for unusual equipment and project-specific workflows.

Built-in drivers

Configure documented equipment in GEM and bring its commands, feedback, and zones into the shared property model.

Open protocols

Work directly with standards including BACnet, Modbus, OPC UA, KNX, MQTT, Matter, Zigbee, Z-Wave, DMX, and OpenADR demand response.

Focused extensions

Use generic transports, APIs, web services, macro scripts, or a custom driver when the project falls outside the catalog.

Serial field equipment can connect through the Omnibus gateway. New or proprietary interfaces can use the GEM developer platform.

Featured open standards

Native protocol support where depth matters.

GEM includes dedicated tools for configuring, mapping, testing, and monitoring supported protocol connections.

OPC UA

Connect to OPC UA servers, discover endpoints, browse address spaces, read and write supported nodes, subscribe to live values, map nodes into GEM zones, and monitor session health.

OpenADR demand response

Enroll as an OpenADR 3.0 or 2.0b Virtual End Node—directly with the utility or through a compatible gateway—then map utility events to load shedding, restore automation, and a permanent event record.

Matter

Expose GEM zones to Apple Home, Google Home, and other Matter ecosystems as a bridge, or commission and control Matter devices directly from GEM as a controller.

MQTT, with a built-in broker

Subscribe and publish against an existing broker, or let GEM host and manage the site’s own Mosquitto broker—users, access rules, TLS listeners, and bridges—from the same admin interface.

Premium driver families

Add the specialized buses the property uses.

Premium drivers are licensed by family for the site rather than by connected device. Feature depth still depends on the selected equipment and integration.

BACnet

Commercial HVAC and building controls over BACnet/IP, with a dedicated explorer for discovery, mapping, live inspection, and diagnostics.

Modbus

Meters, VFDs, boilers, power systems, and industrial equipment over Modbus/TCP or Modbus RTU.

KNX

Lighting, shading, and room control through an existing KNXnet/IP installation.

Lutron

Supported Lutron lighting and shading processors, scenes, occupancy events, and connected controls.

Dante & AES67

A visual routing matrix for Dante and AES67 networked audio, with changes made elsewhere on the network reflected in near real time.

OpenADR VEN

OpenADR 3.0 and 2.0b demand-response programs connected to defined building load strategies.

LoRaWAN

GEM acts as the LoRaWAN network server—no third-party service required—for long-range, low-power environmental, occupancy, leak, and other sensors.

Symetrix Composer

Supported DSP, matrix, source, zone, routing, and audio-processing controls.

Integration catalog

Find the equipment already documented for GEM.

Related model variants are grouped under readable product or protocol families. Use the index to jump by system, or search when JavaScript is available.

Building controls & protocols

Open building buses, supervisory systems, and common transport layers.

  • BACnet/IP
  • Modbus/TCP
  • Modbus RTU
  • KNXnet/IP
  • MQTT
  • MQTT Broker (Mosquitto)
  • OPC UA
  • Tridium Niagara N4 (oBIX)
  • OpenADR 3.0 / 2.0b VEN
  • LoRaWAN Network Server
  • Matter (bridge & controller)
  • Zigbee
  • Z-Wave
  • DMX / Art-Net
  • Creative Lighting eDIDIO (DALI / DMX)
  • Loxone Miniserver
  • Wacnet

HVAC & indoor environment

Thermostats, VRF gateways, air-quality systems, and environmental controls.

  • Airthings Cloud
  • Airzone HVAC
  • Carrier Infinity / Bryant Evolution
  • CoolAutomation CoolMaster
  • Daikin BRP Wi-Fi
  • Daikin Skyport
  • Ecobee
  • Honeywell Total Connect Comfort
  • Lennox S30 / S40
  • Mitsubishi MELCloud
  • Mitsubishi Electric Kumo Cloud
  • Mysa
  • Netatmo
  • Nexia / Trane / American Standard
  • Omnibus VRF
  • Pelican Wireless
  • Rheem EcoNet
  • Sensibo
  • Venstar ColorTouch

Lighting, shades & fans

Architectural lighting, connected lamps, window treatments, and comfort fans.

  • Big Ass Fans
  • Bond Bridge
  • Colorbeam
  • Creative Lighting eDIDIO
  • Elgato Key Light
  • Govee
  • Hunter Douglas PowerView
  • Insteon Hub
  • Leviton Decora Smart Wi-Fi
  • LIFX
  • Lutron Caséta
  • Lutron HomeWorks
  • Lutron QS
  • Lutron RA3 / HomeWorks QSX
  • Modern Forms
  • Nanoleaf
  • Philips Hue
  • Somfy TaHoma
  • Somfy URTSI II
  • Stewart Filmscreen BRIC
  • Vantage InFusion
  • Velux KLF200
  • WiZ
  • WLED
  • Yeelight

Access, security & cameras

Doors, gates, intercoms, alarm panels, video systems, and connected locks.

  • 2N IP Intercom
  • Aiphone IX / IXG
  • Alarm.com
  • Amcrest PTZ
  • August Smart Lock
  • Axis Camera Station
  • Axis VAPIX
  • Brivo
  • ButterflyMX
  • Chamberlain MyQ
  • Comelit ViP / HSrv
  • Dahua cameras, NVRs & intercom events
  • DoorBird
  • DSC PowerSeries Neo
  • Genie Aladdin Connect
  • Grandstream GDS37xx
  • Hikvision
  • Honeywell Vista / AlarmDecoder
  • Kisi
  • Konnected Garage Door Opener
  • Nuki Bridge
  • ONVIF cameras
  • Reolink
  • Ring
  • Salto KS
  • Schlage Encode / Sense+
  • Seam API
  • SkyBell HD
  • Synology Surveillance Station
  • UniFi Access
  • UniFi Protect
  • Verkada Command
  • VISCA over IP

Audio, video & media

Room AV, distributed audio and video, displays, projectors, and media services.

  • Android TV
  • Anthem MRX / AVM
  • Apple TV
  • Atlona AT-OME / AT-UHD
  • AudioControl amplifiers & processors
  • Autonomic Mirage
  • AVPro Edge AC-MAX
  • AVPro Edge AC-MX88
  • AVPro Edge Dante amplifiers
  • AVPro Edge MXNet
  • Barco ClickShare
  • BenQ projectors
  • Biamp Tesira
  • Bluesound / BluOS
  • Bogen Nyquist
  • Bose SoundTouch
  • Bryston SP4
  • Christie projectors
  • Crestron NVX
  • Dante Audio Network
  • Datasat
  • Denon / HEOS
  • DigitaLinx AV over IP
  • DirecTV
  • Epson projectors
  • Extron SIS
  • Just Add Power
  • JVC projectors
  • Kaleidescape
  • KEF Wireless
  • Kramer Protocol 3000
  • LG webOS TVs & commercial displays
  • Lumagen Radiance Pro
  • Marantz
  • McIntosh MA12000
  • Mersive Solstice
  • NEC / Sharp NEC displays
  • Nuvo Concerto / Essentia
  • Onkyo / Integra / Pioneer
  • OPPO Blu-ray
  • Optoma projectors
  • PJLink displays & projectors
  • Plex Media Server
  • PureLink
  • QSC Q-SYS
  • Roku
  • Rotel
  • RTI distributed audio
  • Russound multi-zone audio
  • Samsung TVs & MDC displays
  • Savant Soundbar
  • Séura Outdoor TV
  • Sonos
  • Sony TVs, projectors, receivers & Blu-ray
  • Spotify
  • StormAudio
  • Symetrix Composer
  • Vizio SmartCast
  • VLC Media Player
  • Yamaha MusicCast / YNCA

Power, energy & infrastructure

Electrical systems, solar and storage, EV charging, network power, and field I/O.

  • APC UPS
  • Brainboxes Ethernet I/O
  • Cisco Meraki Dashboard
  • ControlByWeb relay / I/O
  • Cordex HP
  • CyberPower UPS & PDU
  • Emporia Vue
  • Enphase Envoy / IQ Gateway
  • Fronius Solar
  • Global Caché
  • Growatt Solar
  • IoTaWatt
  • Kohler MPAC
  • Netgear managed PoE switches
  • OpenEVSE
  • Opto 22 groov I/O
  • Panamax / Furman
  • Peplink routers & PoE switches
  • Sense Energy Monitor
  • Shelly
  • SMA WebConnect
  • SolarEdge
  • Sol-Ark
  • sonnenBatterie
  • SPAN Smart Panel
  • Tesla Powerwall
  • Tesla Wall Connector
  • TP-Link managed PoE switches
  • Ubiquiti UniFi switches
  • Wallbox
  • WattBox PDU

Water, weather & outdoor

Irrigation, pools and spas, water protection, weather, and outdoor equipment.

  • Ambient Weather Network
  • Hayward OmniLogic
  • Hunter Hydrawise
  • Husqvarna Automower
  • Jandy AquaLink RS
  • Moen Flo
  • OpenSprinkler
  • Orbit B-hyve
  • Pentair IntelliCenter
  • Pentair ScreenLogic
  • Rachio
  • Rain Bird
  • RainMachine
  • Toro Tempus Air
  • WeatherFlow Tempest

Platforms, appliances & services

Connected-home ecosystems, cloud bridges, presence, and appliance services.

  • AVM FRITZ!Box Smart Home
  • Home Connect
  • Hubitat Elevation
  • Meross energy, garage & hub products
  • openHAB
  • OwnTracks
  • Samsung SmartThings
  • SwitchBot Cloud
  • Tasmota
  • TP-Link Kasa
  • Tuya / Smart Life

The catalog reflects documented integration families, not a guarantee that every model, firmware release, command, event, or cloud account type behaves identically. Confirm the exact equipment and required capabilities during engineering.

Don’t see yours?

A documented interface creates options.

GEM can extend beyond its built-in library through open protocols, generic TCP, HTTP, serial and infrared transports, custom web services, and user-authored drivers.

Bring the useful details

Manufacturer, model, firmware, protocol documentation, required commands, and the feedback the property needs.

We’ll tell you whether the best path is an existing driver, a protocol mapping, a focused extension, or new integration work.

Explore the developer platform →

Bring the equipment list.

We’ll map the systems and required capabilities to GEM’s current integration paths and identify what needs deeper engineering.

Ask about your equipment Explore commissioning